Product | Volt | Weight max per leaf |
Angle max per leaf |
Width max per leaf |
Type | Price | Buy |
---|---|---|---|---|---|---|---|
Kit Ace 3TI 230v | 230v |
350kg |
120° |
2.0m |
Linear Ram |
£541.94+vat
|
|
Kit Ace 4TI 230v | 230v |
400kg |
120° |
3.0m |
Linear Ram |
£558.92+vat
|
|
Need this kit in 24v? Click here
The Proteco Kit Ace swing gate kits combine quality performance and sleek design at a competitive price.
The Proteco Kit Ace is powerful, quiet and compact.
Limited Warranty - 3 years on motors, 1 year on other components. See T&C's for more info.
The Proteco Kit Ace has linear ram (straight arm) motors which mount on brackets (highlighted in yellow below) attached to the pillars.
For optimum leverage and mechanical advantage the motors should be mounted where the A & B measurements are equal as displayed in the table below.
Recommended Installation (90° opening)
A + B = C (motor Stroke)
A |
B |
C |
|
Kit Ace 3TI |
150mm | 150mm | 300mm |
Kit Ace 4TI |
200mm | 200mm | 400mm |
If the ideal scenario of A & B is not achievable, refer to the below table to determine bracket position. (mm)
The D dimension only comes into play when the gate is side hung.
ACE 3TI max D measurement = 100mm
ACE 4TI max D measurement = 125mm
Before purchasing this kit it is important to note the width of your post/pillar and hinge position.
Your post/pillar must be wide enough to fix the bracket so the A & B measurements can be achieved for the motor you require.
When fitting the gate brackets to a wooden gate, we recommend that you insert stainless steel tubing (just large enough to sleeve the mounting bolt threads and 1mm shorter than the thickness of the wood) through the gate mounting holes. This will prevent over-tightening of the mounting bolts and also avoid the repetitive push/pull on the mounting bolts from damaging the wood.
These electric gate motors require a physical stop at the end of the opening and closing cycle. Gate Stops provide resistance to the motors so they know they've reached either the open or closed position. Without gate stops the motors will over extend during their operation and the mechanism will eventually fail. When assessing your gate-way it is important to check you can install physical stops in both the closing and opening positions. Common reason's why gate stops cannot be installed are a sloping driveway or the gate is raised significanlty off the ground. If you cannot install something to provide resistance at either end of the motors cycle then you will require a specialised ram with in-built mechanical stops.